50% and 70%, respectively. Receiver-operating curves demonstrated cutoff values for >70% stenosis in C1 when the peak systolic velocity (PSV) was >200 cm/s (specificity, 100%; sensitivity, 71%) or the C1/submandibular ICA index was >3 (specificity, 93%; sensitivity, 86%). CONCLUSIONS:TCCS is a reliable adjunctive method to detect and quantify significant stenosis of the intracranial ICA. The assessment of the C1/ICA index and peak systolic velocities maximizes the diagnostic accuracy of C1 stenosis to >70% when extracranial ICA stenosis coexists. Further studies need to be performed to compare the diagnostic accuracies of MR angiography and TCCS with that of DSA. " />

BACKGROUND AND PURPOSE:Gradation of high-grade intracranial internal carotid artery (ICA) stenosis poses a challenge to noninvasive neurovascular imaging, which seems critical for angioplasty in the ICA segments C1 and C5. We investigated cutoff values of intracranial ICA stenosis for transcranial color-coded sonography (TCCS) and compared this method with the "gold standard," digital subtraction angiography (DSA). MATERIALS AND METHODS:Forty patients (mean age, 58.9 +/- 13.8 years) with intracranial ICA lesions were prospectively examined by using TCCS and DSA. Two standard TCCS coronal imaging planes were used to evaluate the intracranial ICA. In addition, a control group of 128 volunteers without cerebrovascular disease (mean age, 48.8 +/- 15.9 years) was investigated to establish standard velocity values. RESULTS:DSA confirmed 96 stenoses and 8 occlusions of the intracranial ICA in the study population. In 9% and 7% of cases, stenosis confined to the C1 or C5 segment was >50% and 70%, respectively. Receiver-operating curves demonstrated cutoff values for >70% stenosis in C1 when the peak systolic velocity (PSV) was >200 cm/s (specificity, 100%; sensitivity, 71%) or the C1/submandibular ICA index was >3 (specificity, 93%; sensitivity, 86%). CONCLUSIONS:TCCS is a reliable adjunctive method to detect and quantify significant stenosis of the intracranial ICA. The assessment of the C1/ICA index and peak systolic velocities maximizes the diagnostic accuracy of C1 stenosis to >70% when extracranial ICA stenosis coexists. Further studies need to be performed to compare the diagnostic accuracies of MR angiography and TCCS with that of DSA.

译文

+1
+2
100研值 100研值 ¥99课程
检索文献一次
下载文献一次

去下载>

成功解锁2个技能,为你点赞

《SCI写作十大必备语法》
解决你的SCI语法难题!

技能熟练度+1

视频课《玩转文献检索》
让你成为检索达人!

恭喜完成新手挑战

手机微信扫一扫,添加好友领取

免费领《Endnote文献管理工具+教程》

微信扫码, 免费领取

手机登录

获取验证码
登录